\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

江南app官方链接 ip6x测试怎么判断样品壳内压力与壳外是否一致?


2024-10-28


江南app官方链接 的IP6X测试是确保产品防尘性能的关键环节。在这个测试过程中,准确判断样品壳内压力与壳外压力是否一致是一项至关重要的任务。那么,在复杂的IP6X测试环境下,我们该如何准确地判断样品壳内压力与壳外压力是否一致呢?这其中又涉及哪些关键的技术和要点呢?

江南app官方链接

在江南app官方链接 中进行IP6X测试时,判断样品壳内压力与壳外是否一致的方法通常涉及以下几个步骤:

一、.样品的分类:根据GB/T 2423.37-2006/IEC 60068-2-68 1994标准,样品外壳可以分为两种类型:

1.类型1:样品内气压可能会低于环境气压,例如由于运行过程中的热力循环引起的。

2.类型2:在该类型样品内部,不会发生气压低于环境气压的情况。

二、试验前的准备:确保测试样品在测试前进行初始检测,包括外观、基本功能和电性能检测,以保证样品符合测试要求。

3.样品放置:将样品放入江南app官方链接中,样品所占面积不超过试验箱面积的50%,并确保滑石粉用量为2kg/m³。

4.气压控制:通过气压泵在一小时内将试验箱内的气压增加20mbar。如果设备正常工作周期内壳内气压低于周围大气压力,这通常适用于类型1的样品。

5.试验过程:样品在充满滑石粉的环境中暴露,持续时间通常为8小时。

6.样品检查:测试结束后,取出样品进行彻底检查,确认是否有灰尘进入样品内部。如果壳内无明显的灰尘沉积,则认为试验合格。

7.功能测试:检查样品的基本功能和电性能,确保样品在测试后仍能正常工作。

8.评判标准:根据IP6X标准,测试后壳内无灰尘沉积即为合格。

综上所述,关于江南app官方链接ip6x测试怎么判断样品壳内压力与壳外是否一致的介绍。